# '''After power-up''' - the capacity is reset after the controller initialization. However, the capacity from the previous run will be displayed initially until you start the engine.
# '''Power on''' - the capacity is reset after the controller initialization. However, the capacity from the previous run will be displayed initially until you start the engine.
# '''Voltage change''' - capacity is cleared when a battery with a similar (or higher) voltage is connected If the battery is connected to a battery with a higher voltage compared to the maximum voltage of the previous run. This means that every time you connect a fully charged battery of the same composition and cell count, the capacity will be cleared.
# '''Voltage change''' - the capacity is cleared after you connect a battery with a similar (or greater) voltage compared to the maximum battery voltage from the previous run. This means that each time you connect a fully charged battery of the same chemistry and number of cells, the capacity will be cleared.
# '''Manual''' - capacity and energy are never reset and you must reset manually.
# '''Manual''' - the capacity/energy is never cleared and you must perform the reset manually.

Latest revision as of 10:12, 28 August 2024

Message definition (KAVAN Smart PRO SBEC ESCs - Instruction manual)
# '''Power on''' - the capacity is reset after the controller initialization. However, the capacity from the previous run will be displayed initially until you start the engine.
# '''Voltage change''' - the capacity is cleared after you connect a battery with a similar (or greater) voltage compared to the maximum battery voltage from the previous run. This means that each time you connect a fully charged battery of the same chemistry and number of cells, the capacity will be cleared.
# '''Manual''' - the capacity/energy is never cleared and you must perform the reset manually.
  1. Power on - the capacity is reset after the controller initialization. However, the capacity from the previous run will be displayed initially until you start the engine.
  2. Voltage change - the capacity is cleared after you connect a battery with a similar (or greater) voltage compared to the maximum battery voltage from the previous run. This means that each time you connect a fully charged battery of the same chemistry and number of cells, the capacity will be cleared.
  3. Manual - the capacity/energy is never cleared and you must perform the reset manually.