=== Battery charging circuit ===
The battery switch contains a simple battery charging circuit designed for 2S Li-XXX without balancing. The charging may be optionally enabled to keep the backup battery (B2) always ready without needing to remove it from the model (however, we recommend charging the battery with a balancer at least once a month). Several safety conditions are used during the charging:
* The B1 voltage must be higher than the B2 voltage and the B1 must be selected/indicated by the LED.
* The B2 voltage must be within the specified limits (5.5–8.3 V for LiPo/LiIon; 5.0–7.1 V for LiFe).
* The T70 never charges to a full capacity.
* The voltage difference must be lower than 5 V.
* The temperature must be below 70 °C.

Batterieladeschaltung

Die Batterieweiche enthält eine einfache Batterieladeschaltung, die für 2S Li-XXX ohne Balancer ausgelegt ist. Die Ladung kann optional aktiviert werden, um die Backup-Batterie (B2) immer bereit zu halten, ohne sie aus dem Modell entfernen zu müssen (wir empfehlen jedoch, die Batterie mindestens einmal im Monat mit einem Balancer zu laden). Während des Ladevorgangs werden mehrere Sicherheitsbedingungen eingehalten:

  • Die B1-Spannung muss höher sein als die B2-Spannung und B1 muss durch die LED ausgewählt/angezeigt werden.
  • Die B2-Spannung muss innerhalb der angegebenen Grenzen liegen (5,5-8,3 V für LiPo/LiIon; 5,0-7,1 V für LiFe).
  • Die Batterieweiche lädt nie bis zur vollen Kapazität.
  • Die Spannungsdifferenz muss kleiner als 5 V sein.
  • Die Temperatur muss unter 70 °C liegen.