m (FuzzyBot moved page Translations:KAVAN Smart PRO T70 / T70-JR Dual battery switch with telemetry expander - Instruction manual/5/en to Translations:KAVAN Smart PRO T70-C / T70-JR Dual battery switch with telemetry expander - Instruction manual/5/en without leaving a redirect: Part of translatable page "KAVAN Smart PRO T70 / T70-JR Dual battery switch with telemetry expander - Instruction manual") |
(No difference)
|
Revision as of 11:53, 31 October 2024
Technical specifications
T70 | T70-JR | ||
---|---|---|---|
Dimensions | 40×21×6 mm | 40×21×6 mm | |
Weight (incl. cables) | 23 g | 21 g | |
Cables | 1 mm² (17AWG) | 0.5 mm² (20AWG) | |
Connectors | \ | Standard JR | |
Continuous current | 15 A | ||
Peak current (2 s) | 30 A | ||
Standby current | 100 μA | ||
Operating current | 40 mA | ||
Charging current for Batt.2 | up to 200 mA | ||
Operating temperature | (-20)–85 °C | ||
Supply Voltage | 4–12.6 V | ||
Recommended Supply Voltage | 5–8.4 V | ||
Telemetry | FrSky FPort, JETI Duplex EX, Multiplex MSB, Graupner Hott, Futaba S.Bus2, PowerBox P²Bus | ||
Telemetry expander | 2 Extension ports: Duplex EX/EX Bus | ||
Touch switch support | Yes | ||
BEC | No | ||
Selectable Touch/Mechanical/RC switch | Yes | ||
Status LED | Yes |