Translations:KAVAN R6 - User manual/55/en
Custom: The receiver keeps the rate values on all channels as you preselect them. Select the Fail-safe setting menu. Switch from Disconnect/Hold/Not Set to "Custom". Select the channel for which you want to set fail-safe rates and confirm the selection. Then set the rates on each desired channel and confirm the selection. Wait 9 seconds for the Fail-safe setting change to take effect.
Note: If the fail-safe is not set, the model will always operate with the last functional state of the channels before the signal loss. This could potentially cause damage. If the fail-safe is disabled on the RF module side, the receiver will go to the default Hold mode. Do not set the Fail-safe mode for the S.BUS port to No Signal mode, as the signal would be continuously transmitted. Set the S.BUS port to Hold or Custom mode instead.