Actual values – displays the latest telemetry values (current, voltage, capacity, temperature) together with minimums and maximums.
- In the Capacity screen, you can press left+right buttons together to reset the measured capacity.
- Reset Min/Max - press left+right buttons together to reset all minimums and maximums.
Setting – basic settings of the sensor
- Language – you can choose the language of the JETIBOX screen
- Switch type (Touch/Standard) – You can specify which type of switch will be used to the device on and off.
- Touch sensitivity – if the touch switch is used, you can increase its sensitivity by editing this value. Please note that increasing the sensitivity will allow you to install the TW30 directly inside thicker fuselages. On the other hand, this will also make the touch sensor more vulnerable to erroneous inputs.
- Capacity reset – Setting up this parameter will specify at which moment the capacity is reset to zero. Available options:
- Power-On (default) – capacity is reset every time after connecting the battery.
- Voltage-Change – capacity is reset after connecting the battery with a different voltage (by 15 % or more). This way the sensor may distinguish between charged and discharged batteries.
- Manual – capacity is never reset automatically.
- Shutdown voltage – you can specify the minimum voltage for the safe operation of the model. If the voltage goes below the specified level for more than 30 seconds, the TW30 will shut down.