KAVAN C100 Duo - Instruction manual: Difference between revisions
No edit summary |
Mrs. Kavan (talk | contribs) No edit summary |
||
| Line 3: | Line 3: | ||
=== Charger set contents === | === Charger set contents === | ||
KAVAN C100 Duo charger | # KAVAN C100 Duo charger | ||
# Instruction manual | |||
=== Warnings and safety notes === | === Warnings and safety notes === | ||
| Line 20: | Line 21: | ||
=== Specification === | === Specification === | ||
{| class="wikitable" style="text-align: center; width: 100%;" | {| class="wikitable" style="text-align: center; width: 100%;" | ||
|'''DC input voltage''' | |||
|10–30 V max. 35 A | |||
|- | |||
|'''AC input voltage''' | |'''AC input voltage''' | ||
|100–240 V/50–60 Hz | |100–240 V/50–60 Hz | ||
|- | |- | ||
| rowspan="3" |'''Battery types/cells''' | | rowspan="3" |'''Battery types/cells''' | ||
| Line 39: | Line 40: | ||
|2× 0.2–20 A max. 500 W (normal mode) | |2× 0.2–20 A max. 500 W (normal mode) | ||
|- | |- | ||
|1× 0. | |1× 0.1–30 A max. 750 W (parallel mode) | ||
|- | |- | ||
| rowspan="2" |'''Discharging power''' | | rowspan="2" |'''Discharging power''' | ||
|2× 0.2–1. | |2× 0.2–1.5 A max. 15 W (normal mode) | ||
|- | |- | ||
|1× 0.2–3. | |1× 0.2–3.0 A max. 30 W (parallel mode) | ||
|- | |- | ||
|'''Balance current''' | |'''Balance current''' | ||
| Line 53: | Line 54: | ||
|- | |- | ||
|'''USB-C''' | |'''USB-C''' | ||
|Upgrade | |Upgrade USB2.0/USBC PD 30W | ||
|- | |- | ||
|'''Dimension''' | |'''Dimension''' | ||
| | |135x135x64 mm | ||
|- | |- | ||
|'''Weight''' | |'''Weight''' | ||
| Line 64: | Line 65: | ||
=== Charger layout === | === Charger layout === | ||
=== | === Key operation instructions (under standby interface after powering on) === | ||
'''CH1 Menu button:''' Short press to enter the CH1 detailed parameter interface, long press to enter the CH1 task setting menu. | '''CH1 Menu button:''' Short press to enter the CH1 detailed parameter interface, long press to enter the CH1 task setting menu. | ||
| Line 182: | Line 183: | ||
Once satisfied with your settings select “Start” and press the Menu button of the respective channel to start the task. | Once satisfied with your settings select “Start” and press the Menu button of the respective channel to start the task. | ||
You can stop the task in progress anytime; long press the Menu button of the respective channel and then select “Stop” and press the Menu button. | You can stop the task in progress anytime; long press the Menu button of the respective channel and then select “Stop” and press the Menu button. | ||
=== Advanced settings === | |||
Under the standby interface, long press the CH1 and CH2 button at the same time to enter the advanced setting menu. | |||
==== Dual task ==== | |||
Select this setting, the charger will charge/discharge/store to the | |||
two channel batteries with the same parameters at the same time. | |||
Connect the charger with the power supply and power on; select | |||
this setting on the advanced setting menu to set the task parameters. (Note: Both batteries have to be connected to the CH1 and CH2 | |||
outputs before you try to launch the DualTask mode.) | |||
==== Parallel task ==== | |||
Select this setting; it could output Max Power to one battery. Find a power splitter or 1/2 power cord, one end connect with the battery, and the other two ends connect with the battery output port. The battery balance port could connect with any of the charger‘s balance port. Connect the charger with the power supply and power on, and connect your battery as required, select this setting on the advanced setting menu to set the task parameters. | |||
==== DC power CH1 ==== | |||
The charger CH1 is equivalent to a DC power supply when selecting this function, with output voltage adjustable from 2 to 30V, and current adjustable from 1.0 to 5.0A. | |||
==== System setting menu ==== | |||
Under the advanced setting menu, select the system setting into the system setting menu as follows: | |||
===== Lowest input voltage: 10~31V ===== | |||
All tasks in operation will be stopped at once and hint warning of low voltage, when the input voltage is lower than the input voltage as set up. It will protect the battery from being discharged when using battery pack as power supply. | |||
===== Max. input power: 100~1100W ===== | |||
If the input power is smaller than the max. working power (1000W), | |||
please set up the parameter as the actual output power as max | |||
input, to protect the input power and enable the charger to work | |||
stable. | |||
===== Backlight ===== | |||
Adjust the backlight intensity | |||
===== Volume ===== | |||
Adjust the sound signal volume | |||
===== Completion tone ===== | |||
Select the completion tone. | |||
===== USB charge ===== | |||
When this item is set to „Off“, and TYPE-C is the upgrade port. | |||
When this item is set to „On“, TYPE-C acts as a USB charging port and | |||
outputs 5V/2A power. | |||
===== Split screen ===== | |||
There are 3 options of 60 seconds, 30 seconds and OFF for automatic split screen setting. You can choose to switch the display of the | |||
main interface from the single-channel parameter interface to Dual | |||
channel (split screen) parameter interface. | |||
You can also select „Off“ to turn off the automatic split screen function. | |||
===== Language ===== | |||
Select the desired language of the menu. | |||
===== Theme ===== | |||
Select the display style. | |||
===== Keep trickle ===== | |||
After charging is complete, choose whether to continue trickle | |||
charging.<br> | |||
The trickle charge function is enabled to maintain the lithium | |||
battery voltage in a fully charged state; this function is enabled by | |||
default. | |||
===== Self-test ===== | |||
Perform self-test of the charger. | |||
===== Calibration ===== | |||
The input voltage, output voltage and balance voltage of the charger | |||
can be calibrated with this task. | |||
===== System info ===== | |||
Hardware/firmware version information. | |||
=== BattAir === | |||
{{Note|type=reminder|'''Note:''' Only for '''C100 Duo Air''' }} | |||
Batteries with the iSDT Bluetooth Smart module connected (with | |||
pre-set battery data and charge/discharge mode settings using the | |||
BattAir app) allow launching the charge or discharge process right | |||
away, without setting any parameters on your charger. You can find | |||
more information on the use of Smart modules in this video: | |||
https://youtu.be/Wpzb5QsRiX8 | |||
=== EU declaration of conformity (European Union) === | |||
[[File:CE.svg|right|frameless|50x50px]] | |||
Hereby, '''KAVAN Europe s.r.o.''' declares that the '''KAVAN C100 Duo''' is in compliance with the essential requirements as laid down in the EU directive(s) concerning electromagnetic compatibility. The full text of the EU Declaration of Conformity is available at [http://www.kavanrc.com/doc www.kavanrc.com/doc]. | |||
=== Recycling and waste disposal note (European Union) === | |||
[[File:WEEE.svg|right|frameless|50x50px]] | |||
Electrical equipment marked with the crossed-out waste bin symbol must not be discarded in the domestic waste; it should be disposed of via the appropriate specialised disposal system. In the countries of the EU (European Union), electrical devices must not be discarded via the normal domestic waste system (WEEE - Waste of Electrical and Electronic Equipment, Directive 2012/19/EU). You can take your unwanted equipment to your nearest public collection point or recycling centre, where it will be disposed of in the proper manner at no charge to you. By disposing of your old equipment in a responsible manner, you make an important contribution to the safeguarding of the environment. | |||
=== Guarantee === | |||
The KAVAN Europe s.r.o. products are covered by a guarantee that fulfils the currently valid legal requirements in your country. If you wish to make a claim under guarantee, please contact the retailer from whom you first purchased the equipment. The guarantee does not cover faults which were caused in the following ways: crashes, improper use, incorrect connection, reversed polarity, maintenance work carried out late, incorrectly or not at all, or by unauthorised personnel, use of anything other than genuine KAVAN Europe s.r.o. accessories, modifications or repairs which were not carried out by KAVAN Europe s.r.o. or an authorised KAVAN Europe s.r.o., accidental or deliberate damage, defects caused by normal wear and tear, operation outside the Specification, or in conjunction with equipment made by other manufacturers. Please be sure to read the appropriate information sheets in the product documentation. | |||
Revision as of 11:30, 7 November 2025
Introduction
Congratulations on purchasing the KAVAN C100 Duo dual-channel AC/DC balance charger/discharger. This unit is simple to use; however, the proper operation of this charger, as well as the correct usage of your batteries, requires some knowledge on the part of the user. Therefore, it is important to read right through the Operating instructions and Warning and safety notes before you attempt to use your new charger for the first time. We hope you have many years of pleasure and success with your new battery charger.
Charger set contents
- KAVAN C100 Duo charger
- Instruction manual
Warnings and safety notes
- For your safety and a better user experience, please read this manual and follow the instruction before using the new charger.
- This is not a toy. This appliance is not intended for use by young children under 14 years of age or uninformed persons unless they were adequately supervised by a responsible adult person to en sure that they can use the appliance safely.
- Never use the charger without supervision, please stop using the charger and refer to the manual if you encounter any functional abnormality.
- Keep the charger away from dust, humidity, rain, low and high temperature, as well as avoid direct exposure to the sunlight and intense vibration.
- Place the charger on a heat-resisting, non-flammable and insulating surface. Do not use it on the car’s seats, carpet or other similar places. Keep inflammable and explosive objects away from operation areas of the charger.
- Only operate this device in a cool, ventilated area.
- Read the instruction manual carefully to be familiar with the features of the charger, and set proper charging parameters before operating. Setting the parameters incorrectly and or failure to observe safety procedures may and will result in damage to the product, personal property and cause serious injury as well.
- Never attempt to charge primary (non-rechargeable) batteries.
- Batteries pose a severe risk of fire if not properly handled.
- This unit may emit heat during use.
Specification
| DC input voltage | 10–30 V max. 35 A |
| AC input voltage | 100–240 V/50–60 Hz |
| Battery types/cells | LiPo/LiHV/LiFe/Lion: 1–6S |
| NiMH/NiCd: 1–16S | |
| Pb: 1–12S (2–24 V) | |
| Charging power (AC input) | 2× 0.2–20 A max. 200 W (normal mode) |
| Charging power (DC input) | 2× 0.2–20 A max. 500 W (normal mode) |
| 1× 0.1–30 A max. 750 W (parallel mode) | |
| Discharging power | 2× 0.2–1.5 A max. 15 W (normal mode) |
| 1× 0.2–3.0 A max. 30 W (parallel mode) | |
| Balance current | max. 1.5 A/cell |
| Operation temperature range | 0–40°C |
| USB-C | Upgrade USB2.0/USBC PD 30W |
| Dimension | 135x135x64 mm |
| Weight | ca 700 g |
Charger layout
Key operation instructions (under standby interface after powering on)
CH1 Menu button: Short press to enter the CH1 detailed parameter interface, long press to enter the CH1 task setting menu.
CH2 Menu button: Short press to enter the CH2 detailed parameter interface, long press to enter the CH2 task setting menu.
Long press the CH1 and CH2 Menu buttons at the same time: Enter the advanced settings menu.
Preset battery type of charger and task parameters
| Rated voltage | Full charge voltage | Storage voltage | Discharge voltage | Balance charge | Unbalanced charge | Supported cell count | Max. charging current | |
| NiCd/MH | 1.20 V | 1.40 V | No | 0.90 V | No | Yes | 1–16S | 20.0 A |
| Pb | 2.00 V | 2.40 V | No | 1.90 V | No | Yes | 1–12S | 20.0 A |
| LiFe | 3.20 V | 3.65 V | 3.30 V | 2.90 V | Yes | Yes | 1–6S | 20.0 A |
| Lilon | 3.60 V | 4.10 V | 3.70 V | 3.20 V | Yes | Yes | 1–6S | 20.0 A |
| LiPo | 3.70 V | 4.20 V | 3.80 V | 3.30 V | Yes | Yes | 1–6S | 20.0 A |
| LiHV | 3.80 V | 4.35 V | 3.85 V | 3.40 V | Yes | Yes | 1–6S | 20.0 A |
How to confirm charging current
Make sure to know the maximum charging current of the battery before charging, never use excessive current to charge to damage your battery, which will result in overheat even explosion during the charging process. The charging and discharging rate of battery is usually marked with C value. Multiplying the charging C value and battery capacity equals to the maximum charging current supported by the battery. For example, for a 1000mAh battery with a charging rate of 5C, the maximum charging current would be 1000×5=5000 mA; therefore, the maximum charging current is 5 A. For a lithium battery, if it is impossible to confirm the supported charging C value, please set the charging current below 1C, for the sake of its (lithium battery) safety. The reference relation between C value and charging time: charging time ≥60 minutes/ charging C value (e.g. it needs around 60–70 minutes to complete charging with 1C). Due to differences in battery conversion efficiency, the time to complete the charging might be extended.
Operating the charger
Power on your C100 Duo charger connecting to the AC mains socket or car battery/stabilized power supply, connect the battery, and long press the menu button of the desired channel to enter the task setting menu as follows:
| Task | Charge, discharge, destroy, storage |
| Chemistry | LiHV, LiPo, LiIon, LiFe, Pb, NiMH/Cd |
| Condition | Charge/discharge terminal voltage, delta-peak sen sitivity for NiMH/NiCd |
| Cells | LiFe, LiIon, LiPo, LiHV (1–6S); Pb (1–12S); NiMH/Cd (1–16S) |
| Current | 0.2–20.0 A |
Charge
Balancing port is strongly recommended when charging LiPo battery, which can make sure to monitor voltage on each cell battery and balance it when charging. Warning beeper will yell before start charging LiPo if in non-balance mode (no connecting with balance port).
Current setting range: 0.2–20.0 A
Discharge
Current setting range: 0.2–1.5 A
Destroy connect the battery to be scrapped, and select the scrap function in task options, which capable to discharge the battery to 0V.
Storage
Current setting range: 0.2–20.0 A
Starting/stopping the task
Once satisfied with your settings select “Start” and press the Menu button of the respective channel to start the task. You can stop the task in progress anytime; long press the Menu button of the respective channel and then select “Stop” and press the Menu button.
Advanced settings
Under the standby interface, long press the CH1 and CH2 button at the same time to enter the advanced setting menu.
Dual task
Select this setting, the charger will charge/discharge/store to the two channel batteries with the same parameters at the same time. Connect the charger with the power supply and power on; select this setting on the advanced setting menu to set the task parameters. (Note: Both batteries have to be connected to the CH1 and CH2 outputs before you try to launch the DualTask mode.)
Parallel task
Select this setting; it could output Max Power to one battery. Find a power splitter or 1/2 power cord, one end connect with the battery, and the other two ends connect with the battery output port. The battery balance port could connect with any of the charger‘s balance port. Connect the charger with the power supply and power on, and connect your battery as required, select this setting on the advanced setting menu to set the task parameters.
DC power CH1
The charger CH1 is equivalent to a DC power supply when selecting this function, with output voltage adjustable from 2 to 30V, and current adjustable from 1.0 to 5.0A.
Under the advanced setting menu, select the system setting into the system setting menu as follows:
Lowest input voltage: 10~31V
All tasks in operation will be stopped at once and hint warning of low voltage, when the input voltage is lower than the input voltage as set up. It will protect the battery from being discharged when using battery pack as power supply.
Max. input power: 100~1100W
If the input power is smaller than the max. working power (1000W), please set up the parameter as the actual output power as max input, to protect the input power and enable the charger to work stable.
Backlight
Adjust the backlight intensity
Volume
Adjust the sound signal volume
Completion tone
Select the completion tone.
USB charge
When this item is set to „Off“, and TYPE-C is the upgrade port. When this item is set to „On“, TYPE-C acts as a USB charging port and outputs 5V/2A power.
Split screen
There are 3 options of 60 seconds, 30 seconds and OFF for automatic split screen setting. You can choose to switch the display of the main interface from the single-channel parameter interface to Dual channel (split screen) parameter interface. You can also select „Off“ to turn off the automatic split screen function.
Language
Select the desired language of the menu.
Theme
Select the display style.
Keep trickle
After charging is complete, choose whether to continue trickle
charging.
The trickle charge function is enabled to maintain the lithium
battery voltage in a fully charged state; this function is enabled by
default.
Self-test
Perform self-test of the charger.
Calibration
The input voltage, output voltage and balance voltage of the charger can be calibrated with this task.
System info
Hardware/firmware version information.
BattAir
Batteries with the iSDT Bluetooth Smart module connected (with pre-set battery data and charge/discharge mode settings using the BattAir app) allow launching the charge or discharge process right away, without setting any parameters on your charger. You can find more information on the use of Smart modules in this video: https://youtu.be/Wpzb5QsRiX8
EU declaration of conformity (European Union)

Hereby, KAVAN Europe s.r.o. declares that the KAVAN C100 Duo is in compliance with the essential requirements as laid down in the EU directive(s) concerning electromagnetic compatibility. The full text of the EU Declaration of Conformity is available at www.kavanrc.com/doc.
Recycling and waste disposal note (European Union)

Electrical equipment marked with the crossed-out waste bin symbol must not be discarded in the domestic waste; it should be disposed of via the appropriate specialised disposal system. In the countries of the EU (European Union), electrical devices must not be discarded via the normal domestic waste system (WEEE - Waste of Electrical and Electronic Equipment, Directive 2012/19/EU). You can take your unwanted equipment to your nearest public collection point or recycling centre, where it will be disposed of in the proper manner at no charge to you. By disposing of your old equipment in a responsible manner, you make an important contribution to the safeguarding of the environment.
Guarantee
The KAVAN Europe s.r.o. products are covered by a guarantee that fulfils the currently valid legal requirements in your country. If you wish to make a claim under guarantee, please contact the retailer from whom you first purchased the equipment. The guarantee does not cover faults which were caused in the following ways: crashes, improper use, incorrect connection, reversed polarity, maintenance work carried out late, incorrectly or not at all, or by unauthorised personnel, use of anything other than genuine KAVAN Europe s.r.o. accessories, modifications or repairs which were not carried out by KAVAN Europe s.r.o. or an authorised KAVAN Europe s.r.o., accidental or deliberate damage, defects caused by normal wear and tear, operation outside the Specification, or in conjunction with equipment made by other manufacturers. Please be sure to read the appropriate information sheets in the product documentation.